Fire Sprinkler Inspection, Testing, & Repair
A sprinkler system spends years doing nothing and then has to work perfectly on the worst day the building will ever have. The problem is that it can be out of service without giving you any sign — a valve closed during maintenance and never reopened, a gauge reading nothing, corrosion narrowing a pipe from the inside.
We inspect and test the parts that determine whether the system will actually deliver water, on the schedule the local codes in Toronto and Ontario require, and we document every result so there’s no argument later about what was checked and when.
What we actually do
Inspect and test wet, dry, pre-action and deluge systems: control and sectional valves, gauges, alarm and supervisory devices, waterflow alarms, main drain tests, dry-pipe trip tests, air compressors, antifreeze loops, sprinkler head condition and clearances, and spare head cabinets.
On the multi-year cycle we carry out internal pipe inspections and obstruction investigations — the checks that find corrosion and scale before they find you.
How often it’s due
Weekly and monthly gauge and valve checks as well as air pressure on dry stems. Additionally, there should be quarterly checks of waterflow alarm devices, supervisory signals, and hydraulic nameplates. The system needs to undergo a full annual inspection, with a main drain test and valve testing. Every five years there should be an internal inspection of piping for obstruction and corrosion.
Why teams call us
Because we can do the next step. Most sprinkler deficiencies aren’t a service call, they’re a small project — a section of pipe, a valve, a head replacement program across a floor. Sigma designs and installs sprinkler systems as well as servicing them, so the fix doesn’t need a new vendor, a new quote and a new site walk.
Services we perform on this system
Inspection, Testing, & Maintenance
One coordinated inspection, testing and maintenance program for every life-safety system, scheduled to code and documented in one place.
Learn more →Design, Installation & Retrofit
Engineered design, permit drawings and full installation of fire alarm, sprinkler and standpipe systems — including retrofits and upgrades in…
Learn more →Repair & 24/7 Emergency Service
Corrective and emergency repair for sprinkler, alarm, pump, extinguisher, lighting, door and damper deficiencies, 24/7.
Learn more →Fire Alarm Monitoring
24/7 central-station monitoring of fire alarm and sprinkler signals, with immediate dispatch and a full event log.
Learn more →Frequently asked questions
How often do sprinkler systems need to be inspected in Ontario?
There isn’t one date — there’s a cycle. Some checks are weekly or monthly and can be done by building staff; alarm devices are quarterly; a full inspection and main drain test is annual; and piping gets an internal inspection every five years. We put the whole cycle on one schedule and tell you what’s coming.
What is the five-year internal inspection, and do we really need it?
It means opening the system at set points to look inside the pipe for corrosion, scale and obstructions. It’s the only way to find a problem that’s building up invisibly, and yes — it’s required. It’s also the inspection most likely to have been skipped by a previous vendor.
If you find a problem, can you fix it?
Yes, and usually with the same crew. Small deficiencies get corrected on the visit. Anything larger we quote with a clear scope, and our own installers do the work.
A sprinkler head is leaking. What should we do right now?
Call our 24/7 line before you close any valve. Shutting the wrong valve can take far more of the building out of service than you intend, and an impairment has to be managed and documented properly.
Is your building in full compliance?